Skip to content

@mega-yfue/eufy-sdk / SolixSocParams

Interface: SolixSocParams ​

The Solarbank's battery SOC-limit settings — the param_data block read from / written to site/get_site_device_param under param_type "27" (verified live on an AE103). All values are whole-percent integers. chargeUpperLimit caps charging (the app's "charge limit" / max SOC) and dischargeLowerLimit floors discharging (the "discharge limit" / minimum SOC — the same quantity the realtime b5 telemetry blob reports). backupReserve (+ its switch) is the reserved-for-outage SOC; socCalibrationEnable is the periodic full-cycle calibration toggle. The wire keys are the snake_case form (charge_upper_limit, discharge_lower_limit, backup_reserve, backup_reserve_switch, soc_calibration_enable).

Properties ​

backupReserve ​

ts
backupReserve: number;

backupReserveSwitch ​

ts
backupReserveSwitch: number;

chargeUpperLimit ​

ts
chargeUpperLimit: number;

dischargeLowerLimit ​

ts
dischargeLowerLimit: number;

socCalibrationEnable ​

ts
socCalibrationEnable: number;

Independent and unofficial. Not affiliated with, endorsed by, or sponsored by Anker Innovations, Anker eufy, or eufy. "Anker eufy", "eufy" and "Anker" are trademarks of their respective owners. Use responsibly — rapid or failed logins can trigger captcha or temporary cooldowns.